single ended - definição. O que é single ended. Significado, conceito
Diclib.com
Dicionário ChatGPT
Digite uma palavra ou frase em qualquer idioma 👆
Idioma:

Tradução e análise de palavras por inteligência artificial ChatGPT

Nesta página você pode obter uma análise detalhada de uma palavra ou frase, produzida usando a melhor tecnologia de inteligência artificial até o momento:

  • como a palavra é usada
  • frequência de uso
  • é usado com mais frequência na fala oral ou escrita
  • opções de tradução de palavras
  • exemplos de uso (várias frases com tradução)
  • etimologia

O que (quem) é single ended - definição

SIGNAL TRANSMISSION MECHANISM IN WIRES
Single-ended signalling; Single-ended signal

single ended      
<hardware> An electrical connection where one wire carries the signal and another wire or shield is connected to electrical ground. This is in contrast to a differential connection where the second wire carries an inverted signal.
Single-ended signaling         
Single-ended signaling is the simplest and most commonly used method of transmitting electrical signals over wires. One wire carries a varying voltage that represents the signal, while the other wire is connected to a reference voltage, usually ground.
Single-ended recuperative burner         
TYPE OF GAS BURNER
Single ended recuperative burner
A single-ended recuperative (SER) burner is a type of gas burner used in high-temperature industrial kilns and furnaces. These burners are used where indirect heating is required, e.

Wikipédia

Single-ended signaling

Single-ended signaling is the simplest and most commonly used method of transmitting electrical signals over wires. One wire carries a varying voltage that represents the signal, while the other wire is connected to a reference voltage, usually ground. The main alternative to single-ended signaling is called differential signaling where the two conductors carry signals equal in magnitude but of opposite electric polarity.

Single-ended signaling is less expensive to implement than differential, but it has a distinct disadvantage: a single-ended system requires a power supply voltage equal to the maximum amplitude of the signal to be received whereas a differential system only requires a voltage half of the signal amplitude to be received. For a given power supply voltage then, a differential system produces signals of twice the amplitude and therefore has twice as good noise immunity (6 dB higher signal-to-noise ratio) as a single-ended system.

The main advantage of single-ended over differential signaling is that fewer wires are needed to transmit multiple signals. If there are n signals, then there are n+1 wires, one for each signal and one for ground, while differential signaling uses at least 2n wires. A disadvantage of single-ended systems that utilize a common return is that the return currents for all the signals use the same conductor (even if separate ground wires are used, the grounds are inevitably connected together at each end), and this can sometimes cause interference (crosstalk) between the signals.